STAN040-FCS - Plan 54 forced circulation system, floor mounted with 40 Litre tank

The STAN040-FCS is a 40 Litre (10.7 US Gal) Oil Forced Circulation System, suitable for API Plan 54 applications.

It is typically floor or skid mounted and is manufactured from 316 Stainless Steel. It is supplied with a Temperature, Pressure and Level Gauge.

The suction filter incorporates a 60 micron stainless steel mesh to help prevent contaminants entering the system. The tank incorporates a filler breather cap and a cast iron electric motor.

The system circulates oil via a positive displacement pump delivering up to 4 L/min (1.0 US Gal/min) to the mechanical seal for cooling and lubrication. Cool fluid to the seal faces, helps improve mechanical seal longevity.

Pressure is controlled in the delivery pipework by a back pressure control valve allowing the main tank to be unpressurised. Oil temperature is dissipated via an integral plate heat exchanger.

SIZE: Compact Plan 54 system measures 600mm x 300mm x 600mm high (23.6" x 11.8" x 23.6" high)

Stanseals has a range of Forced Circulation Systems (FCS) including STAN100-FCS (100L tank) and STAN012-FCS (12L tank)

Enquire Now
Supply/Design Characteristics
Seal Shaft Sizes
System Vessel Size
40 Litres (10.7 US Gals)
Inboard Seal Face Combination
Outboard Seal Face Combination
Gasket
Secondary Sealing
Bellows
Inboard Wetted Parts
Elastomers
Shaft Speeds
Pressures
25 Barg (362 psig) ** (optional systems available for 42 Barg / 610 psig)
Temperature
Max. Tank Temp: 80 Deg C (176 Deg F) **
Instrumention
Oil Filled Pressure Gauge, IP66 Variable Speed Motor, Flow Gauge
Pipework & Fittings
Integral Hard Piped. All Fittings Included. Flexible stainless steel hose kit to the mechanical seal (length depending on installation position)
Temperatures
Max. Tank Temp: 80 Deg C (176 Deg F) **

Other Information:

316 Stainless Steel construction

Optional Extras:

  • ATEX Certification
  • Integral Cooling Coil (inside the vessel)
  • Air Blast Cooler
  • Fully instrumented with high/low pressure switches

System Safe Operating Limits:

This seal support system incorporates best practice features and innovation as detailed in our technical blogs and white papers.

** Apply "industry standard" Pressure and Temperature de-rating factors, by application. The safe system performance characteristics are typical characteristics for each variable in isolation. The individual upper limit values of each variable should NOT be used in multiple combinations of Pressure and Temperature. Contact our Technical Sales Department for further details.

In accordance with industry best practice, each STANSEALS seal support system incorporates a permanently secured label, to the vessel, that confirms the design and operational limits of the system.

No items found.